Journal Article
Multicenter Study
Add like
Add dislike
Add to saved papers

Results of the First U.S. FDA-Approved Hip Resurfacing Device at 10-Year Follow-up.

BACKGROUND: The BIRMINGHAM HIP Resurfacing (BHR) system is a metal-on-metal hip implant system approved by the U.S. Food and Drug Administration in 2006. The approval required a multicenter, prospective, post-market-approval study. Our purpose is to report the current results at 10 years of follow-up.

METHODS: Between October 2006 and December 2009, 280 primary BHR procedures were performed at 5 sites. Outcome measures included Kaplan-Meier survivorship, reasons for revision, radiographic component stability and osteolysis, Harris hip scores, and metal levels including cobalt and chromium. The mean age at the time of the procedure was 51.3 ± 7.1 years, 74% (206) of 280 BHRs were implanted in male patients, the mean body mass index was 27.8 ± 4.4 kg/m2, and 95% (265) of 280 hips had a primary diagnosis of osteoarthritis. The mean follow-up among all 280 hips was 9.0 ± 2.5 years. Prior to 10-year follow-up, 20 hips were revised and 5 patients representing 5 hips had died. Among the remaining 255 hips, 218 (85%) met the minimum follow-up of 10 years.

RESULTS: The 10-year survival free from all-cause component revision was 92.9% (95% confidence interval [CI], 89.8% to 96.1%) for all hips and 96.0% (95% CI, 93.1% to 98.9%) among male patients <65 years old at the time of the procedure. Reasons for revision included femoral loosening (n = 5), femoral neck fracture (n = 3), pseudotumor (n = 3), osteolysis (n = 2), and acetabular loosening (n = 1), as well as 6 revisions for a combination of pain, noise, or metal levels. Among unrevised hips, the median Harris hip score improved from preoperatively (59) to 1 year postoperatively (99; p < 0.001) and remained stable through 10 years postoperatively (99; p = 0.08). Radiographically, 5% (10) of 218 unrevised hips had osteolysis with no component migration. Median metal levels had increased at 1 year postoperatively (cobalt: from 0.12 ppb preoperatively to 1.5 ppb at 1 year postoperatively, p < 0.001; chromium: from 0.6 ppb preoperatively to 1.7 ppb at 1 year postoperatively, p < 0.001), then remained stable through 5 years before slightly decreasing at 10 years postoperatively (cobalt: 1.3 ppb, p < 0.001; chromium: 1.4 ppb, p < 0.001).

CONCLUSIONS: This prospective, multicenter, post-market-approval study demonstrated that the BHR implant system is safe and effective through 10 years of follow-up, particularly among young male patients.

LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app