We have located links that may give you full text access.
JOURNAL ARTICLE
REVIEW
Ventriculoatrial Shunts: Review of Technical Aspects and Complications.
World Neurosurgery 2022 Februrary
Diversion of cerebrospinal fluid is required in many neurosurgical conditions. When a standard ventriculoperitoneal shunt and endoscopic third ventriculostomy are not appropriate options, placement of a ventriculoatrial shunt is a safe, relatively familiar second-line shunting procedure. Herein we reviewed the technical aspects of ventriculoatrial shunt placement using an illustrative case. We focused on the different modalities for inserting and confirming the location of the distal catheter tip. We discussed how to overcome typical difficulties and significant concerns, such as cardiac arrhythmias and venous thrombosis. In addition, we reviewed the current literature for the different complications associated with ventriculoatrial shunt placement.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app