We have located links that may give you full text access.
Diagnostic outcome and safety of plugged liver biopsy in high-risk patients: a systematic review and meta-analysis.
Acta Radiologica 2023 January 25
BACKGROUND: Percutaneous liver biopsy is the gold standard test for the assessment of liver disease. In patients with coagulopathy, ascites, post-transplantation, and hypervascular tumors, biopsy is associated with increased risk of adverse events (AEs). Transjugular liver biopsy (TJLB) is recommended in these conditions but is expensive and unavailable at many centers. Plugged liver biopsy (PLB) provides an alternate diagnostic modality in these high-risk cases.
PURPOSE: To analyze the pooled diagnostic outcome and safety of PLB in high-risk cases.
MATERIAL AND METHODS: A literature search of various databases from January 1990 to July 2022 was conducted for studies evaluating the outcome of PLB in high-risk cases. The primary outcomes were pooled sample adequacy and AEs. Pooled event rates across studies were expressed with summative statistics.
RESULTS: A total of 17 studies (2329 patients) were included in the meta-analysis. The pooled proportion of sample adequacy was 98.9% (95% confidence interval [CI]=98.2-99.6). Severe AEs, major bleeding, and minor AEs were seen in 0.7% (95% CI=0.1-1.3), 0.4% (95% CI=0.1-0.8), and 11.5% (95% CI=2.4-20.6) of the patients. There was only one reported mortality, giving a pooled incidence of 0.0002% (95% CI=0.0-0.0038). Compared to TJLB (5 studies, n = 336), there was no difference in either sample adequacy (odds ratio [OR]=2.34, 95% CI=0.83-6.58) or risk of serious AEs (OR=0.47, 95% CI=0.173-1.31).
CONCLUSION: PLB can be safely performed on patients with coagulopathy and/or ascites with high sample adequacy rates and low incidence of AEs and mortality.
PURPOSE: To analyze the pooled diagnostic outcome and safety of PLB in high-risk cases.
MATERIAL AND METHODS: A literature search of various databases from January 1990 to July 2022 was conducted for studies evaluating the outcome of PLB in high-risk cases. The primary outcomes were pooled sample adequacy and AEs. Pooled event rates across studies were expressed with summative statistics.
RESULTS: A total of 17 studies (2329 patients) were included in the meta-analysis. The pooled proportion of sample adequacy was 98.9% (95% confidence interval [CI]=98.2-99.6). Severe AEs, major bleeding, and minor AEs were seen in 0.7% (95% CI=0.1-1.3), 0.4% (95% CI=0.1-0.8), and 11.5% (95% CI=2.4-20.6) of the patients. There was only one reported mortality, giving a pooled incidence of 0.0002% (95% CI=0.0-0.0038). Compared to TJLB (5 studies, n = 336), there was no difference in either sample adequacy (odds ratio [OR]=2.34, 95% CI=0.83-6.58) or risk of serious AEs (OR=0.47, 95% CI=0.173-1.31).
CONCLUSION: PLB can be safely performed on patients with coagulopathy and/or ascites with high sample adequacy rates and low incidence of AEs and mortality.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.