Journal Article
Multicenter Study
Add like
Add dislike
Add to saved papers

Multicentric investigation on the safety, feasibility and usability of the ABLE lower-limb robotic exoskeleton for individuals with spinal cord injury: a framework towards the standardisation of clinical evaluations.

BACKGROUND: Robotic lower-limb exoskeletons have the potential to provide additional clinical benefits for persons with spinal cord injury (SCI). However, high variability between protocols does not allow the comparison of study results on safety and feasibility between different exoskeletons. We therefore incorporated key aspects from previous studies into our study protocol and accordingly conducted a multicentre study investigating the safety, feasibility and usability of the ABLE Exoskeleton in clinical settings.

METHODS: In this prospective pretest-posttest quasi-experimental study across two SCI centres in Germany and Spain, in- and outpatients with SCI were recruited into a 12-session training and assessment protocol, utilising the ABLE Exoskeleton. A follow-up visit after 4 weeks was included to assess after-training outcomes. Safety outcomes (device-related adverse events (AEs), number of drop-outs), feasibility and usability measures (level of assistance, donning/doffing-time) were recorded at every session together with changes in gait parameters and function. Patient-reported outcome measures including the rate of perceived exertion (RPE) and the psychosocial impact of the device were performed. Satisfaction with the device was evaluated in both participants and therapists.

RESULTS: All 24 participants (45 ± 12 years), with mainly subacute SCI (< 1 year after injury) from C5 to L3, (ASIA Impairment Scale A to D) completed the follow-up. In 242 training sessions, 8 device-related AEs (pain and skin lesions) were reported. Total time for don and doff was 6:50 ± 2:50 min. Improvements in level of assistance and gait parameters (time, steps, distance and speed, p < 0.05) were observed in all participants. Walking function and RPE improved in participants able to complete walking tests with (n = 9) and without (n = 6) the device at study start (p < 0.05). A positive psychosocial impact of the exoskeleton was reported and the satisfaction with the device was good, with best ratings in safety (participants), weight (therapists), durability and dimensions (both).

CONCLUSIONS: Our study results prove the feasibility of safe gait training with the ABLE Exoskeleton in hospital settings for persons with SCI, with improved clinical outcomes after training. Our study protocol allowed for consistent comparison of the results with other exoskeleton trials and can serve as a future framework towards the standardisation of early clinical evaluations. Trial Registration https://trialsearch.who.int/ , DRKS00023503, retrospectively registered on November 18, 2020.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app