Add like
Add dislike
Add to saved papers

Feasibility of artificial intelligence assisted quantitative muscle ultrasound in carpal tunnel syndrome.

BACKGROUND: In case of focal neuropathy, the muscle fibers innervated by the corresponding nerves are replaced with fat or fibrous tissue due to denervation, which results in increased echo intensity (EI) on ultrasonography. EI analysis can be conducted quantitatively using gray scale analysis. Mean value of pixel brightness of muscle image defined as EI. However, the accuracy achieved by using this parameter alone to differentiate between normal and abnormal muscles is limited. Recently, attempts have been made to increase the accuracy using artificial intelligence (AI) in the analysis of muscle ultrasound images. CTS is the most common disease among focal neuropathy. In this study, we aimed to verify the utility of AI assisted quantitative analysis of muscle ultrasound in CTS.

METHODS: This is retrospective study that used data from adult who underwent ultrasonographic examination of hand muscles. The patient with CTS confirmed by electromyography and subjects without CTS were included. Ultrasound images of the unaffected hands of patients or subjects without CTS were used as controls. Ultrasonography was performed by one physician in same sonographic settings. Both conventional quantitative grayscale analysis and machine learning (ML) analysis were performed for comparison.

RESULTS: A total of 47 hands with CTS and 27 control hands were analyzed. On conventional quantitative analysis, mean EI ratio (i.e. mean thenar EI/mean hypothenar EI ratio) were significantly higher in the patient group than in the control group, and the AUC was 0.76 in ROC analysis. In the analysis using machine learning, the AUC was the highest for the linear support vector classifier (AUC = 0.86). When recursive feature elimination was applied to the classifier, the AUC value improved to 0.89.

CONCLUSION: This study showed a significant increase in diagnostic accuracy when AI was used for quantitative analysis of muscle ultrasonography. If an analysis protocol using machine learning can be established and mounted on an ultrasound machine, a noninvasive and non-time-consuming muscle ultrasound examination can be conducted as an ancillary tool for diagnosis.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app