Identification of patent foramen ovale permitting paradoxic embolism.
Journal of the American College of Cardiology 1995 October
OBJECTIVES: We sought to analyze the morphologic and functional characteristics of the patent foramen ovale in patients with different clinical likelihoods for paradoxic embolism.
BACKGROUND: The incidence of patent foramen ovale is increased in patients with otherwise unexplained arterial ischemic events. Because signs of venous thrombosis are absent in most patients, the diagnosis of paradoxic embolism is often questioned, even when patent foramen ovale is the only potential explanation for the ischemic event.
METHODS: Seventy-eight patients with a patent foramen ovale detected by contrast transesophageal echocardiography were studied: 21 patients with an otherwise unexplained arterial ischemic event and clinical evidence implying paradoxic embolism (group I), 30 patients with an unexplained ischemic event but no clinical evidence for paradoxic embolism (group II) and 27 patients without an ischemic event (group III).
RESULTS: During transesophageal contrast echocardiography, patients in group I had more severe right to left shunting (mean +/- SD 52 +/- 16% of the left atrial area filled with contrast medium) and a wider opening of the patent foramen ovale (7.1 +/- 3.6-mm separation between the septum primum and the septum secundum) than did patients in group II (35 +/- 15% and 4.4 +/- 3.2 mm, respectively, p < 0.001) or group III (23 +/- 12% and 3.0 +/- 2.0 mm, respectively, p < 0.001). The incidence of atrial septal aneurysm was similar in the three groups. Severe contrast shunting (> or = 50% of the left atrial area filled with contrast medium) and wide opening of the patent foramen ovale (> or = 5-mm separation) revealed a high sensitivity (71% and 86%, respectively) and high specificity (86% and 96%, respectively) for identification of group I patients.
CONCLUSIONS: Right to left contrast shunting is more severe and opening of the patent foramen ovale is larger in patients with ischemic arterial events considered to be due to paradoxic embolism. In patients with a patent foramen ovale as the only potential cause for ischemic events and no signs of venous thrombosis, morphologic and functional variables assessed by transesophageal echocardiography may be helpful in estimating the likelihood of paradoxic embolism.
BACKGROUND: The incidence of patent foramen ovale is increased in patients with otherwise unexplained arterial ischemic events. Because signs of venous thrombosis are absent in most patients, the diagnosis of paradoxic embolism is often questioned, even when patent foramen ovale is the only potential explanation for the ischemic event.
METHODS: Seventy-eight patients with a patent foramen ovale detected by contrast transesophageal echocardiography were studied: 21 patients with an otherwise unexplained arterial ischemic event and clinical evidence implying paradoxic embolism (group I), 30 patients with an unexplained ischemic event but no clinical evidence for paradoxic embolism (group II) and 27 patients without an ischemic event (group III).
RESULTS: During transesophageal contrast echocardiography, patients in group I had more severe right to left shunting (mean +/- SD 52 +/- 16% of the left atrial area filled with contrast medium) and a wider opening of the patent foramen ovale (7.1 +/- 3.6-mm separation between the septum primum and the septum secundum) than did patients in group II (35 +/- 15% and 4.4 +/- 3.2 mm, respectively, p < 0.001) or group III (23 +/- 12% and 3.0 +/- 2.0 mm, respectively, p < 0.001). The incidence of atrial septal aneurysm was similar in the three groups. Severe contrast shunting (> or = 50% of the left atrial area filled with contrast medium) and wide opening of the patent foramen ovale (> or = 5-mm separation) revealed a high sensitivity (71% and 86%, respectively) and high specificity (86% and 96%, respectively) for identification of group I patients.
CONCLUSIONS: Right to left contrast shunting is more severe and opening of the patent foramen ovale is larger in patients with ischemic arterial events considered to be due to paradoxic embolism. In patients with a patent foramen ovale as the only potential cause for ischemic events and no signs of venous thrombosis, morphologic and functional variables assessed by transesophageal echocardiography may be helpful in estimating the likelihood of paradoxic embolism.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app