We have located links that may give you full text access.
Journal Article
Research Support, Non-U.S. Gov't
Hemochromatosis: diagnosis and quantification of liver iron with gradient-echo MR imaging.
Radiology 1994 November
PURPOSE: To assess the role of magnetic resonance (MR) imaging in detection and quantification of liver iron overload.
MATERIALS AND METHODS: MR imaging at 0.5 T was prospectively performed on 77 patients (67 with liver iron overload and 10 without) who underwent a liver biopsy with biochemical determination of the liver iron concentration (LIC) (normal, < 36 mumol per gram of liver tissue [dry weight]). Ratios of signal intensities and liver T2 relaxation time were calculated from images obtained with spin-echo and breath-hold gradient-echo (GRE) sequences.
RESULTS: Liver-to-tissue signal intensity ratios were better correlated with LIC than T2 relaxation time. Long-echo-time GRE sequences were the most sensitive for detection of slight overload. Thus, high sensitivity (94%) and specificity (90%) were obtained with a liver-to-fat ratio threshold of 1. The quantification of iron with MR imaging was accurate when the LIC was 80-300 mumol/g. For heavy overload, above 300 mumol/g, quantification was impossible owing to complete signal loss. Pancreatic and splenic signal intensity were unchanged in most cases.
CONCLUSION: This method, which can be improved by using more sensitive sequences with a high-field-strength system, should be competitive with biopsy for the diagnosis of substantial liver iron overload.
MATERIALS AND METHODS: MR imaging at 0.5 T was prospectively performed on 77 patients (67 with liver iron overload and 10 without) who underwent a liver biopsy with biochemical determination of the liver iron concentration (LIC) (normal, < 36 mumol per gram of liver tissue [dry weight]). Ratios of signal intensities and liver T2 relaxation time were calculated from images obtained with spin-echo and breath-hold gradient-echo (GRE) sequences.
RESULTS: Liver-to-tissue signal intensity ratios were better correlated with LIC than T2 relaxation time. Long-echo-time GRE sequences were the most sensitive for detection of slight overload. Thus, high sensitivity (94%) and specificity (90%) were obtained with a liver-to-fat ratio threshold of 1. The quantification of iron with MR imaging was accurate when the LIC was 80-300 mumol/g. For heavy overload, above 300 mumol/g, quantification was impossible owing to complete signal loss. Pancreatic and splenic signal intensity were unchanged in most cases.
CONCLUSION: This method, which can be improved by using more sensitive sequences with a high-field-strength system, should be competitive with biopsy for the diagnosis of substantial liver iron overload.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app