We have located links that may give you full text access.
Comparative Study
Journal Article
Research Support, Non-U.S. Gov't
Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients.
BACKGROUND AND PURPOSE: The prevalence of a patent foramen ovale has been shown to be increased in patients with ischemic stroke. Transesophageal echocardiography, transthoracic echocardiography, and transcranial Doppler examination with contrast injection can all be used to search for a patent foramen ovale. We compared the accuracy of these techniques for identifying a patent foramen ovale in 49 patients with acute ischemic stroke or transient ischemic attack.
METHODS: Transcranial Doppler examination of the right middle cerebral artery was performed during simultaneous transthoracic echocardiography with aerated saline injection, and again during transesophageal echocardiography; the latter was adopted as the "gold standard" for assessing the sensitivity of the other two tests.
RESULTS: Contrast transesophageal echocardiography detected a patent foramen ovale in 19 of 49 patients (39%), during normal respiration in 15 of them and during Valsalva maneuver in 4. Transcranial Doppler correctly identified 13 patients with a patent foramen ovale and all 30 patients without it. Therefore, the sensitivity of transcranial Doppler was 68% (13/19), and its specificity 100% (30/30). The 6 patients misclassified by transcranial Doppler (false negatives) had a very small right-to-left shunt detected by transesophageal echocardiography. Contrast transthoracic echocardiography was found to be the least sensitive test, detecting a patent foramen ovale in only 9 of 19 patients (47%). The specificity of transthoracic echocardiography was 100% (30/30 patients). The low sensitivity of transthoracic echocardiography was principally due to the suboptimal image quality obtained in false-negative patients. Both transcranial Doppler and transthoracic echocardiography were more sensitive in patients with cryptogenic stroke than in patients with stroke of determined origin. This may indicate the presence of larger, more easily detectable shunts in patients with cryptogenic stroke.
CONCLUSIONS: Transesophageal echocardiography is more sensitive than transcranial Doppler examination in detecting a patent foramen ovale, but only in cases of minimal right-to-left shunts, the clinical relevance of which remains to be established. The sensitivity of transthoracic echocardiography is heavily hampered by the frequency of inadequate heart visualization.
METHODS: Transcranial Doppler examination of the right middle cerebral artery was performed during simultaneous transthoracic echocardiography with aerated saline injection, and again during transesophageal echocardiography; the latter was adopted as the "gold standard" for assessing the sensitivity of the other two tests.
RESULTS: Contrast transesophageal echocardiography detected a patent foramen ovale in 19 of 49 patients (39%), during normal respiration in 15 of them and during Valsalva maneuver in 4. Transcranial Doppler correctly identified 13 patients with a patent foramen ovale and all 30 patients without it. Therefore, the sensitivity of transcranial Doppler was 68% (13/19), and its specificity 100% (30/30). The 6 patients misclassified by transcranial Doppler (false negatives) had a very small right-to-left shunt detected by transesophageal echocardiography. Contrast transthoracic echocardiography was found to be the least sensitive test, detecting a patent foramen ovale in only 9 of 19 patients (47%). The specificity of transthoracic echocardiography was 100% (30/30 patients). The low sensitivity of transthoracic echocardiography was principally due to the suboptimal image quality obtained in false-negative patients. Both transcranial Doppler and transthoracic echocardiography were more sensitive in patients with cryptogenic stroke than in patients with stroke of determined origin. This may indicate the presence of larger, more easily detectable shunts in patients with cryptogenic stroke.
CONCLUSIONS: Transesophageal echocardiography is more sensitive than transcranial Doppler examination in detecting a patent foramen ovale, but only in cases of minimal right-to-left shunts, the clinical relevance of which remains to be established. The sensitivity of transthoracic echocardiography is heavily hampered by the frequency of inadequate heart visualization.
Full text links
Related Resources
Trending Papers
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Eosinophilic Esophagitis: Clinical Pearls for Primary Care Providers and Gastroenterologists.Mayo Clinic Proceedings 2024 April
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app