AJR. American Journal of Roentgenology 1996 September
OBJECTIVE: We compared color Doppler velocity sonography and color Doppler energy sonography for the diagnosis of spermatic cord torsion in a canine model and determined the degree of torsion necessary to acutely halt testicular blood flow.
MATERIALS AND METHODS: Spermatic cord torsion was created in five dogs by exposing and rotating the ipsilateral testis 0 degree, 180 degrees, 270 degrees, 360 degrees, 450 degrees, and 540 degrees. Detorsion followed. The testicles were scanned at each torsion stop using both color Doppler velocity sonography and color Doppler energy sonography. Doppler parameters were optimized (by phantom and test scans) and maintained at a tolerable noise level throughout the experiment. Readers who were unaware of the degree of torsion compared flow in the rotated and contralateral control testes.
RESULTS: Flow became undetectable by color Doppler velocity sonography and color Doppler energy sonography at 450 degrees in four of five cases and at 540 degrees in one of five cases. We found no significant difference between the velocity and the energy techniques for detecting this absence of flow (p > .05, Wilcoxon test). We found a significant difference in degree of flow for both techniques when comparing controls and all degrees of torsion combined (p < .006, Mann-Whitney test), but significance was achieved at lesser degrees of torsion with the velocity technique than with the energy technique (180 degrees and 360 degrees, respectively, Wilcoxon test).
CONCLUSION: Color Doppler energy sonography was not significantly more sensitive than color Doppler velocity sonography for the diagnosis of spermatic cord torsion in this model. Complete occlusion of arterial inflow occurred at 450-540 degrees of torsion.
MATERIALS AND METHODS: Spermatic cord torsion was created in five dogs by exposing and rotating the ipsilateral testis 0 degree, 180 degrees, 270 degrees, 360 degrees, 450 degrees, and 540 degrees. Detorsion followed. The testicles were scanned at each torsion stop using both color Doppler velocity sonography and color Doppler energy sonography. Doppler parameters were optimized (by phantom and test scans) and maintained at a tolerable noise level throughout the experiment. Readers who were unaware of the degree of torsion compared flow in the rotated and contralateral control testes.
RESULTS: Flow became undetectable by color Doppler velocity sonography and color Doppler energy sonography at 450 degrees in four of five cases and at 540 degrees in one of five cases. We found no significant difference between the velocity and the energy techniques for detecting this absence of flow (p > .05, Wilcoxon test). We found a significant difference in degree of flow for both techniques when comparing controls and all degrees of torsion combined (p < .006, Mann-Whitney test), but significance was achieved at lesser degrees of torsion with the velocity technique than with the energy technique (180 degrees and 360 degrees, respectively, Wilcoxon test).
CONCLUSION: Color Doppler energy sonography was not significantly more sensitive than color Doppler velocity sonography for the diagnosis of spermatic cord torsion in this model. Complete occlusion of arterial inflow occurred at 450-540 degrees of torsion.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app