Photorefractive keratectomy for compound myopic astigmatism with an eye cup erodible mask delivery system.
Journal of Refractive Surgery 1996 May
BACKGROUND: The erodible mask is a new energy delivery system for the 193-nm argon fluoride excimer laser. It consists of a polymethyl-methacrylate button, whose profile is transferred by photoablation onto the corneal surface. We present the 6- and 12-month results of this technique in the correction of compound myopic astigmatism.
METHODS: We performed the mask procedure on 21 eyes of 16 subjects (mean age, 30.7 years; range, 24 to 46) to correct combined myopia and astigmatism. Attempted myopic correction ranged between -1.50 diopters (D) and -10.00 D (mean, -7.07 D). Attempted astigmatic correction ranged between -1.50 D and -4.00 D (mean, -2.46 D).
RESULTS: Mean procedure error was: sphere +0.74 D (range, -3.00/+5.00), cylinder -1.41 D (range, -3.50/0.00) at 1 month after surgery; sphere +0.18 D (range, -2.50/+ 3.50), cylinder -1.56 D (range, -4.00/0.00) at 6 months; and sphere -1.30 D (range, -3.00/0.00), cylinder was -1.25 D (range, -2.00/-0.50) at 12 months (10 eyes). During follow up, haze values were never higher than 1, except for one case of haze 2 that regressed to 0 during follow up. Postoperative uncorrected visual acuity improved in all eyes where emmetropia was envisaged; none of the eyes lost spectacle-corrected visual acuity lines 6 or 12 months after surgery.
CONCLUSIONS: The erodible mask proved effective and fairly predictable mainly in the correction of the spherical component of refractive error, while the correction of astigmatism revealed greater unpredictability, with a constant trend to undercorrection.
METHODS: We performed the mask procedure on 21 eyes of 16 subjects (mean age, 30.7 years; range, 24 to 46) to correct combined myopia and astigmatism. Attempted myopic correction ranged between -1.50 diopters (D) and -10.00 D (mean, -7.07 D). Attempted astigmatic correction ranged between -1.50 D and -4.00 D (mean, -2.46 D).
RESULTS: Mean procedure error was: sphere +0.74 D (range, -3.00/+5.00), cylinder -1.41 D (range, -3.50/0.00) at 1 month after surgery; sphere +0.18 D (range, -2.50/+ 3.50), cylinder -1.56 D (range, -4.00/0.00) at 6 months; and sphere -1.30 D (range, -3.00/0.00), cylinder was -1.25 D (range, -2.00/-0.50) at 12 months (10 eyes). During follow up, haze values were never higher than 1, except for one case of haze 2 that regressed to 0 during follow up. Postoperative uncorrected visual acuity improved in all eyes where emmetropia was envisaged; none of the eyes lost spectacle-corrected visual acuity lines 6 or 12 months after surgery.
CONCLUSIONS: The erodible mask proved effective and fairly predictable mainly in the correction of the spherical component of refractive error, while the correction of astigmatism revealed greater unpredictability, with a constant trend to undercorrection.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
The Effect of Albumin Administration in Critically Ill Patients: A Retrospective Single-Center Analysis.Critical Care Medicine 2024 Februrary 8
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app