We have located links that may give you full text access.
Excimer laser photorefractive keratectomy to correct astigmatism.
PURPOSE: To evaluate the efficacy of excimer laser photorefractive keratectomy (PRK) to correct astigmatism.
SETTING: Hôpital Morvan, Brest, France.
METHODS: A 193 nm excimer laser was used to perform toric ablation with an expanding slit to flatten the cornea in the steeper meridian and/or to correct myopia with an iris diaphragm in 72 eyes (55 patients): 68 eyes for compound myopic astigmatism and 4 for astigmatism only.
RESULTS: Preoperative cylinder was -2.14 diopters (D) +/- 1.99 (SD) (range -0.50 to -5.50 D); 6 months postoperatively, it was -1.75 +/- 1.34 D (range -0.25 to -5.25 D). Preoperative spherical equivalent was -5.33 +/- 3.22 D (range -0.25 to -14.50 D); 6 months postoperatively, it was -0.86 +/- 2.32 D (range 2.50 to -9.75 D). The axial error was within 30 degrees. Uncorrected visual acuity was 0.50 or better in 64.5% of patients.
CONCLUSIONS: Overall patient satisfaction seemed the result of the myopic correction; cylindrical correction was incomplete. Future software refinements should improve the results. In particular, single elliptical ablation seems to offer theoretical advantages.
SETTING: Hôpital Morvan, Brest, France.
METHODS: A 193 nm excimer laser was used to perform toric ablation with an expanding slit to flatten the cornea in the steeper meridian and/or to correct myopia with an iris diaphragm in 72 eyes (55 patients): 68 eyes for compound myopic astigmatism and 4 for astigmatism only.
RESULTS: Preoperative cylinder was -2.14 diopters (D) +/- 1.99 (SD) (range -0.50 to -5.50 D); 6 months postoperatively, it was -1.75 +/- 1.34 D (range -0.25 to -5.25 D). Preoperative spherical equivalent was -5.33 +/- 3.22 D (range -0.25 to -14.50 D); 6 months postoperatively, it was -0.86 +/- 2.32 D (range 2.50 to -9.75 D). The axial error was within 30 degrees. Uncorrected visual acuity was 0.50 or better in 64.5% of patients.
CONCLUSIONS: Overall patient satisfaction seemed the result of the myopic correction; cylindrical correction was incomplete. Future software refinements should improve the results. In particular, single elliptical ablation seems to offer theoretical advantages.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Anti-Arrhythmic Effects of Heart Failure Guideline-Directed Medical Therapy and Their Role in the Prevention of Sudden Cardiac Death: From Beta-Blockers to Sodium-Glucose Cotransporter 2 Inhibitors and Beyond.Journal of Clinical Medicine 2024 Februrary 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app