Intracerebral depth electrode monitoring in partial epilepsy: the morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery.

Neurosurgery 1996 August
OBJECTIVE: To determine the indications for, efficacy of, and safety of depth electrode placement using magnetic resonance imaging (MRI)-guided stereotactic surgery in patients with intractable epilepsy.

METHODS: We analyzed retrospectively the results of depth electrode usage in 50 consecutive patients at the University of Michigan Hospitals studied in the years 1991 through 1994, using MRI-guided stereotactic implantation, in conjunction with simultaneous subdural strip electrode recordings.

RESULTS: There were no deaths, no infections, and no new neurological deficits. One small subdural hematoma adjacent to a subdural strip electrode was evacuated to prevent interference with ictal recording. Two cylindrical subdural electrodes were found to be intraparenchymal, as revealed by postoperative MRI, and were removed. One patient was unintentionally left alone briefly, and he pulled out the electrodes while confused postictally, requiring a subsequent operation for replacement. Ictal onset zones were successfully localized in 47 patients.

CONCLUSION: We have found intracerebral electrode placement to be as safe as subdural strip electrode placement and have found combined depth and strip electrode monitoring to be highly effective in localizing the onset zones of complex partial seizures. Intracranial monitoring was particularly useful in the detection of a single ictal onset zone in the absence of neuroimaging abnormality and in the definitive diagnosis of bilateral independent ictal onset zones in the temporal lobe epilepsy syndrome. The specific technical aspects of the procedure that contribute to a successful outcome are reviewed. A comparison with earlier reported series suggests that MRI-guided stereotaxy and pial inspection may reduce complications of depth electrode placement.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app