We have located links that may give you full text access.
Comparative Study
Journal Article
Transmesenteric-transfemoral method of intrahepatic portosystemic shunt placement with minilaparotomy.
PURPOSE: To determine whether the transmesenteric-transfemoral method of intrahepatic portosystemic shunt (IPS) placement is safer and more efficient than the transjugular method.
PATIENTS AND METHODS: Sixty-six consecutive patients with cirrhosis and bleeding varices underwent 67 IPS procedures. Sixty-one of these procedures were performed using a combination of transfemoral access to the hepatic vein with transmesenteric access to the portal system provided by means of minilaparotomy. Follow-up days were collected periodically by means of clinical evaluation and duplex sonography of the shunt. Angiographic evaluation was performed when necessary.
RESULTS: No technical failures or periprocedural deaths occurred. The radiologic and surgical portions of the procedure were accomplished within 45 and 55 minutes, respectively. In cases without portal thrombosis, maximum fluoroscopy time was 12 minutes. During follow-up (mean, 16 months), eight shunt revisions including one additional shunt placement were necessary.
CONCLUSION: Transmesenteric-transfemoral IPS placement requires surgical participation but may offer improved efficiency and safety compared with regular transjugular IPS placement.
PATIENTS AND METHODS: Sixty-six consecutive patients with cirrhosis and bleeding varices underwent 67 IPS procedures. Sixty-one of these procedures were performed using a combination of transfemoral access to the hepatic vein with transmesenteric access to the portal system provided by means of minilaparotomy. Follow-up days were collected periodically by means of clinical evaluation and duplex sonography of the shunt. Angiographic evaluation was performed when necessary.
RESULTS: No technical failures or periprocedural deaths occurred. The radiologic and surgical portions of the procedure were accomplished within 45 and 55 minutes, respectively. In cases without portal thrombosis, maximum fluoroscopy time was 12 minutes. During follow-up (mean, 16 months), eight shunt revisions including one additional shunt placement were necessary.
CONCLUSION: Transmesenteric-transfemoral IPS placement requires surgical participation but may offer improved efficiency and safety compared with regular transjugular IPS placement.
Full text links
Related Resources
Trending Papers
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Eosinophilic Esophagitis: Clinical Pearls for Primary Care Providers and Gastroenterologists.Mayo Clinic Proceedings 2024 April
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app