Comparison of eye position versus computer identified microcalcification clusters on mammograms.
Medical Physics 1997 January
The purpose of this study was to compare identifications of microcalcification clusters on mammograms by a computerized detection scheme and by human observers having their eye position recorded. Eighty digitized mammograms (half with a subtle microcalcification cluster) were analyzed by a computerized detection scheme and then were read from laser-printed films by six mammographers while eye position was recorded. The computer had 83% true positives with a false-positive rate of 0.5 per image. The true positives of the radiologists ranged from 78% to 90%, with false-positive rates ranging from 0.03 to 0.20. Locations of true and false positives identified by computer and by the human were compared. All but 5% of the true clusters were identified by either the computer, human, or by both. Here 10% of the clusters were detected by only the computer, and 11% were missed by the computer but detected by at least one radiologist. False positives were of three types: identified by computer only, by the human reader only, or by both. Eye-position data indicated significant differences in dwell time between both true-positive and false-positive locations reported by the radiologist versus the computer detections. A follow-up analysis indicated that microcalcification clusters and false positives were judged to have more identifiable characteristics of true calcifications and were associated with longer gaze durations than those with fewer microcalcification characteristics. In general, the computer was able to detect clusters judged to have few or no features that the radiologists were not able to detect. Comparison of computer versus human identification of microcalcification clusters may be useful for improving computerized detection schemes to serve as clinical aids to mammographers, and for understanding what image features lead to false-positive decisions for both the computer and the human reader.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app