We have located links that may give you full text access.
Predictive value of technetium Tc 99m-labeled red blood cell scintigraphy for positive angiogram in massive lower gastrointestinal hemorrhage.
Diseases of the Colon and Rectum 1997 April
PURPOSE: This study was performed to evaluate whether the time interval from injection of technetium Tc 99m (99mTc)-labeled red blood cells to the time of a radionuclide "blush" (positive scan) can be used to improve the efficacy in predicting a positive angiogram.
METHOD: A retrospective review revealed 160 patients who received 99mTc-labeled red blood cell scintigraphy for evaluation of massive lower gastrointestinal hemorrhage between 1989 and 1994. Patients were included who demonstrated signs of shock on admission, had an initial decrease in hematocrit of > or = 6 percent, or required a minimum transfusion of two units of packed red blood cells. Scanning duration was 90 minutes, with imaging every 2 minutes. Time interval from injection to a positive scan was analyzed to determine predictability of a positive angiography.
RESULTS: Of 160 patients, 86 demonstrated positive scans, of whom 47 underwent angiography. These 47 patients were divided into two groups according to scan results. Group 1 (n = 33) had immediate appearance of blush; Group 2 (n = 14) had blush after two minutes. In Group 1, 20 of 33 patients had a positive angiogram, yielding a positive predictive value of 60 percent (P = 0.033). Of the 14 patients with negative angiograms (13 from Group 1, and 1 with a negative scan), 6 had radiographic occlusion of the inferior mesenteric artery and 1 had spasm of the right colic artery, with scans that blushed in the respective distributions. Excluding these seven patients yielded a positive predictive value of 75 percent (P = 0.0072) for angiography. In patients with a delayed blush (Group 2), 13 of 14 had negative angiograms, yielding a negative predictive value of 93 percent (92 percent excluding those with nonvisualization of the inferior mesenteric artery). Twenty of 21 (95 percent) positive angiograms occurred in Group 1 patients. Of the 27 patients with negative angiograms, 13 were Group 2 patients.
CONCLUSION: Patients with immediate blush on 99mTc-labeled red blood cell scintigraphy required urgent angiography. Patients with delayed blush have low angiographic yields. These data suggest that patients with delayed blush or negative scans may be observed and evaluated with colonoscopy.
METHOD: A retrospective review revealed 160 patients who received 99mTc-labeled red blood cell scintigraphy for evaluation of massive lower gastrointestinal hemorrhage between 1989 and 1994. Patients were included who demonstrated signs of shock on admission, had an initial decrease in hematocrit of > or = 6 percent, or required a minimum transfusion of two units of packed red blood cells. Scanning duration was 90 minutes, with imaging every 2 minutes. Time interval from injection to a positive scan was analyzed to determine predictability of a positive angiography.
RESULTS: Of 160 patients, 86 demonstrated positive scans, of whom 47 underwent angiography. These 47 patients were divided into two groups according to scan results. Group 1 (n = 33) had immediate appearance of blush; Group 2 (n = 14) had blush after two minutes. In Group 1, 20 of 33 patients had a positive angiogram, yielding a positive predictive value of 60 percent (P = 0.033). Of the 14 patients with negative angiograms (13 from Group 1, and 1 with a negative scan), 6 had radiographic occlusion of the inferior mesenteric artery and 1 had spasm of the right colic artery, with scans that blushed in the respective distributions. Excluding these seven patients yielded a positive predictive value of 75 percent (P = 0.0072) for angiography. In patients with a delayed blush (Group 2), 13 of 14 had negative angiograms, yielding a negative predictive value of 93 percent (92 percent excluding those with nonvisualization of the inferior mesenteric artery). Twenty of 21 (95 percent) positive angiograms occurred in Group 1 patients. Of the 27 patients with negative angiograms, 13 were Group 2 patients.
CONCLUSION: Patients with immediate blush on 99mTc-labeled red blood cell scintigraphy required urgent angiography. Patients with delayed blush have low angiographic yields. These data suggest that patients with delayed blush or negative scans may be observed and evaluated with colonoscopy.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app