Late results of bioprosthetic tricuspid valve replacement in Ebstein's anomaly.
Annals of Thoracic Surgery 1998 November
BACKGROUND: Historically, porcine bioprosthetic valves have poor durability in pediatric patients; nearly half will require replacement within 5 years. However, our early experience with patients having Ebstein's anomaly suggests that tricuspid bioprostheses in this anomaly might have better durability.
METHODS: One hundred fifty-eight patients who received a primary tricuspid bioprosthesis because of tricuspid valve anatomy unsuitable for repair between April 1972 and January 1997 were reviewed. Results were analyzed and Kaplan-Meier curves were constructed to estimate patient survival and probability of remaining free of reoperation.
RESULTS: Follow-up of 149 patients (94.3%) who survived 30 days ranged up to 17.8 years (mean, 4.5 years). Ten-year survival was 92.5%+/-2.5% (SE), 129 late survivors (92.1%) were in New York Heart Association class I or II, and 93.6% were free of anticoagulation. Freedom from bioprosthesis replacement was 97.5%+/-1.9% at 5 years and 80.6%+/-7.6% at 10 and 15 years.
CONCLUSIONS: Bioprosthesis durability in the tricuspid position in patients with Ebstein's anomaly compares very favorably with bioprosthesis durability in other cardiac valve positions, especially for pediatric patients, and also compares favorably with tricuspid bioprosthesis durability in patients with other diagnoses.
METHODS: One hundred fifty-eight patients who received a primary tricuspid bioprosthesis because of tricuspid valve anatomy unsuitable for repair between April 1972 and January 1997 were reviewed. Results were analyzed and Kaplan-Meier curves were constructed to estimate patient survival and probability of remaining free of reoperation.
RESULTS: Follow-up of 149 patients (94.3%) who survived 30 days ranged up to 17.8 years (mean, 4.5 years). Ten-year survival was 92.5%+/-2.5% (SE), 129 late survivors (92.1%) were in New York Heart Association class I or II, and 93.6% were free of anticoagulation. Freedom from bioprosthesis replacement was 97.5%+/-1.9% at 5 years and 80.6%+/-7.6% at 10 and 15 years.
CONCLUSIONS: Bioprosthesis durability in the tricuspid position in patients with Ebstein's anomaly compares very favorably with bioprosthesis durability in other cardiac valve positions, especially for pediatric patients, and also compares favorably with tricuspid bioprosthesis durability in patients with other diagnoses.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
The Effect of Albumin Administration in Critically Ill Patients: A Retrospective Single-Center Analysis.Critical Care Medicine 2024 Februrary 8
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app