Posterior corneal surface topographic changes after laser in situ keratomileusis are related to residual corneal bed thickness.
Ophthalmology 1999 Februrary
OBJECTIVE: To determine whether ectasia after laser in situ keratomileusis (LASIK) is related to residual corneal bed thickness.
DESIGN: Retrospective noncomparative case series.
PARTICIPANTS: Thirty-two eyes of 16 patients with refractive errors of -4.00 to -18.00 diopters were examined.
INTERVENTION: LASIK was performed. The topography of the posterior corneal surface was examined with the Orbscan slit scanning corneal topography/pachymetry system.
MAIN OUTCOME MEASURES: The difference in the elevation of posterior corneal surface regarding the best-fit sphere was measured.
RESULTS: After surgery, mean bulge of 17.2 +/- 7.2 microns was found in eyes with residual corneal bed of 250 microns or greater, whereas 41.0 +/- 22.1 microns was seen in eyes with bed thickness less than 250 microns (t = 4.29; P = 0.000).
CONCLUSION: Posterior corneal bulge is correlated with the residual corneal bed thickness. The risk of ectasia may be increased if the residual corneal bed is thinner than 250 microns.
DESIGN: Retrospective noncomparative case series.
PARTICIPANTS: Thirty-two eyes of 16 patients with refractive errors of -4.00 to -18.00 diopters were examined.
INTERVENTION: LASIK was performed. The topography of the posterior corneal surface was examined with the Orbscan slit scanning corneal topography/pachymetry system.
MAIN OUTCOME MEASURES: The difference in the elevation of posterior corneal surface regarding the best-fit sphere was measured.
RESULTS: After surgery, mean bulge of 17.2 +/- 7.2 microns was found in eyes with residual corneal bed of 250 microns or greater, whereas 41.0 +/- 22.1 microns was seen in eyes with bed thickness less than 250 microns (t = 4.29; P = 0.000).
CONCLUSION: Posterior corneal bulge is correlated with the residual corneal bed thickness. The risk of ectasia may be increased if the residual corneal bed is thinner than 250 microns.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Anti-Arrhythmic Effects of Heart Failure Guideline-Directed Medical Therapy and Their Role in the Prevention of Sudden Cardiac Death: From Beta-Blockers to Sodium-Glucose Cotransporter 2 Inhibitors and Beyond.Journal of Clinical Medicine 2024 Februrary 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app